Focusrite Pro Important Information Guide provides links to:
RedNet Control
RedNet PCIe drivers (included with RedNet Control download)
Audinate Dante Controller (installed with RedNet Control)
System Requirements:
Mac OS X:
10.13 macOS High Sierra
10.14 macOS Mojave
10.15 macOS Catalina
10.16 macOS Big Sur
Windows:
Windows 10 (32/ 64 bit)
Feature Specifications:
Input / Output Trim
Input Trim: -78 to 0dB in 1dB steps
(per channel)
Output Trim: -78 to 0dB in 1dB steps (per
channel)
Input Sample Rate Convertors
Sample Rate Range: 32 to 216 kHz
Gain Error: -0.3dB
Dynamic Range: > 138dB (-60 dBFS
method)
THD + N: < -130dB (0.00003%); 0
dBFS input
Latency: 11 to 45 samples (network and input
sample rate dependent
Input: 1 x RCA phono socket
(replaces DB-25 channels 3-4)
Output: 1 x RCA phono socket
(switchable, duplicates any DB-25 channel pair)
Word Clock
Word Clock Input: 1 x BNC 75Ω port (Switchable Termination)
Word Clock Output: 1 x BNC 75Ω port
PSU & Network Connections
PSU: 2 x IEC Inputs with retaining
clips.
Network: 2 x etherCON NE8FBH-S, also compatible
with standard RJ45 connectors (Accomodates rugged etherCON NE8MC*. Does not
intermate with Cat 6 cable connector NE8MC6-MO and NKE65* cable)
Front Panel Indicators
Primary PSU (A): Green LED. Illuminates
when an AC input is applied and all DC outputs are present.
Secondary PSU (B): Green LED.
Illuminates when an AC input is applied and all DC outputs are present.
Primary Network: Green LED.
Indicates that a network connection is present on primary port when in
redundant mode. When in Switched mode, a valid network connection at either
Primary or Secondary network port will cause this LED to illuminate.
Secondary Network: Green LED.
Indicates that a network connection is present on secondary port when in
redundant mode. Not used in switched mode.
Network Locked: Green LED. When
unit is network slave, shows valid network lock. When unit is network master,
shows lock to indicated clock source. Flashing indicates external clock is
selected but not connected.
Sample Rate: Orange LED for each:
44.1 kHz, 48 kHz, x2, x4.
Pull Up/Down: Orange LED. Indicates
unit is set to operate on a Dante pull up/down domain.
Signal Indicators: 16 Green LEDs, 8
input/8 output indicators. Illuminate @ -126dBFS.
Clock Source: Orange LED for each:
Internal, Word Clock, DARS, Input 1–2 and Input 9–10.
Network Modes
Redundant: Allows unit to connect
to two independent networks.
Switched: Connects both ports to
integrated network switch allowing daisy-chaining of devices.
Power
PSU: 2 x Internal, 100-240V, 50/60Hz, consumption 30W
Heat Performance
Operating Temperature: Operates at up to an ambient temperature of 50 degrees Celcius
Product Dimensions:
482mm (18.98") width x 282.7mm (11.13") depth x 44mm (1.73") height